{"product_id":"electric-scalpel-vessel-sealing-ligasure-for-veterinary","title":"Electric Scalpel Vessel Sealing Ligasure for Veterinary","description":"\u003cp data-start=\"83\" data-end=\"504\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"87\" data-end=\"125\"\u003eLigasure Electrosurgical Generator\u003c\/strong\u003e is a high-performance surgical energy platform designed to provide precise cutting, coagulation and advanced vessel sealing during a wide range of surgical procedures. Featuring both monopolar and bipolar operation, the system delivers consistent energy output with intelligent tissue monitoring, helping clinicians achieve effective haemostasis while minimising thermal spread.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"506\" data-end=\"751\"\u003eDesigned for hospitals, surgical centres and specialist clinics, the generator offers intuitive touchscreen operation, multiple power modes and compatibility with a wide range of electrosurgical accessories. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"753\" data-end=\"756\"\u003e\n\u003ch1 data-section-id=\"u0ybrq\" data-start=\"758\" data-end=\"772\"\u003eKey Features\u003c\/h1\u003e\n\u003cul data-start=\"774\" data-end=\"1274\"\u003e\n\u003cli data-section-id=\"49azpt\" data-start=\"774\" data-end=\"810\"\u003eAdvanced vessel sealing technology\u003c\/li\u003e\n\u003cli data-section-id=\"1k19je8\" data-start=\"811\" data-end=\"849\"\u003eMonopolar and bipolar electrosurgery\u003c\/li\u003e\n\u003cli data-section-id=\"1abmvjc\" data-start=\"850\" data-end=\"888\"\u003eHigh-frequency digital energy output\u003c\/li\u003e\n\u003cli data-section-id=\"v57ws2\" data-start=\"889\" data-end=\"930\"\u003eIntelligent tissue impedance monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"ci4zpb\" data-start=\"931\" data-end=\"961\"\u003eLarge colour LCD touchscreen\u003c\/li\u003e\n\u003cli data-section-id=\"161y586\" data-start=\"962\" data-end=\"987\"\u003eUser-friendly interface\u003c\/li\u003e\n\u003cli data-section-id=\"1ydjh91\" data-start=\"988\" data-end=\"1019\"\u003eFast response energy delivery\u003c\/li\u003e\n\u003cli data-section-id=\"zxgdnf\" data-start=\"1020\" data-end=\"1060\"\u003eMultiple cutting and coagulation modes\u003c\/li\u003e\n\u003cli data-section-id=\"po25aj\" data-start=\"1061\" data-end=\"1110\"\u003eReturn Electrode Monitoring (REM) safety system\u003c\/li\u003e\n\u003cli data-section-id=\"1kbkr4y\" data-start=\"1111\" data-end=\"1137\"\u003eCompact, portable design\u003c\/li\u003e\n\u003cli data-section-id=\"z406lm\" data-start=\"1138\" data-end=\"1185\"\u003eSuitable for continuous operating theatre use\u003c\/li\u003e\n\u003cli data-section-id=\"1vcxbzu\" data-start=\"1186\" data-end=\"1274\"\u003eCE certified medical equipment (model dependent) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1276\" data-end=\"1279\"\u003e\n\u003ch1 data-section-id=\"1m9gx28\" data-start=\"1281\" data-end=\"1304\"\u003eClinical Applications\u003c\/h1\u003e\n\u003cp data-start=\"1306\" data-end=\"1319\"\u003eSuitable for:\u003c\/p\u003e\n\u003cul data-start=\"1321\" data-end=\"1586\"\u003e\n\u003cli data-section-id=\"yrdjoj\" data-start=\"1321\" data-end=\"1338\"\u003eGeneral Surgery\u003c\/li\u003e\n\u003cli data-section-id=\"qcr36p\" data-start=\"1510\" data-end=\"1586\"\u003eVeterinary Surgery (selected models) \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1588\" data-end=\"1591\"\u003e\n\u003ch1 data-section-id=\"cnfs9v\" data-start=\"1593\" data-end=\"1613\"\u003eSurgical Functions\u003c\/h1\u003e\n\u003ch3 data-section-id=\"1syazkj\" data-start=\"1615\" data-end=\"1636\"\u003eMonopolar Cutting\u003c\/h3\u003e\n\u003cul data-start=\"1638\" data-end=\"1677\"\u003e\n\u003cli data-section-id=\"uozlg8\" data-start=\"1638\" data-end=\"1648\"\u003ePure Cut\u003c\/li\u003e\n\u003cli data-section-id=\"1qave4i\" data-start=\"1649\" data-end=\"1662\"\u003eBlend Cut I\u003c\/li\u003e\n\u003cli data-section-id=\"1v3mevf\" data-start=\"1663\" data-end=\"1677\"\u003eBlend Cut II\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"g6juiz\" data-start=\"1679\" data-end=\"1704\"\u003eMonopolar Coagulation\u003c\/h3\u003e\n\u003cul data-start=\"1706\" data-end=\"1739\"\u003e\n\u003cli data-section-id=\"10bxwsq\" data-start=\"1706\" data-end=\"1719\"\u003eFulguration\u003c\/li\u003e\n\u003cli data-section-id=\"13pu4en\" data-start=\"1720\" data-end=\"1739\"\u003eSpray Coagulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1rpjqzn\" data-start=\"1741\" data-end=\"1764\"\u003eBipolar Coagulation\u003c\/h3\u003e\n\u003cul data-start=\"1766\" data-end=\"1796\"\u003e\n\u003cli data-section-id=\"4ubs2e\" data-start=\"1766\" data-end=\"1796\"\u003eStandard Bipolar Coagulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"wml6av\" data-start=\"1798\" data-end=\"1816\"\u003eVessel Sealing\u003c\/h3\u003e\n\u003cp data-start=\"1818\" data-end=\"2057\"\u003eAdvanced bipolar vessel sealing technology designed for permanent sealing of vessels up to \u003cstrong data-start=\"1909\" data-end=\"1929\"\u003e7 mm in diameter\u003c\/strong\u003e, providing secure haemostasis while reducing the need for traditional ligatures or clips. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"2059\" data-end=\"2062\"\u003e\n\u003ch1 data-section-id=\"zjxypn\" data-start=\"2064\" data-end=\"2090\"\u003eTechnical Specifications\u003c\/h1\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2092\" data-end=\"2650\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2092\" data-end=\"2119\"\u003e\n\u003ctr data-start=\"2092\" data-end=\"2119\"\u003e\n\u003cth data-start=\"2092\" data-end=\"2108\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"2108\" data-end=\"2119\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2149\" data-end=\"2650\"\u003e\n\u003ctr data-start=\"2149\" data-end=\"2210\"\u003e\n\u003ctd data-start=\"2149\" data-end=\"2166\" data-col-size=\"sm\"\u003eGenerator Type\u003c\/td\u003e\n\u003ctd data-start=\"2166\" data-end=\"2210\" data-col-size=\"sm\"\u003eHigh Frequency Electrosurgical Generator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2211\" data-end=\"2267\"\u003e\n\u003ctd data-start=\"2211\" data-end=\"2229\" data-col-size=\"sm\"\u003eOperating Modes\u003c\/td\u003e\n\u003ctd data-start=\"2229\" data-end=\"2267\" data-col-size=\"sm\"\u003eMonopolar, Bipolar, Vessel Sealing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2268\" data-end=\"2296\"\u003e\n\u003ctd data-start=\"2268\" data-end=\"2285\" data-col-size=\"sm\"\u003eMain Frequency\u003c\/td\u003e\n\u003ctd data-start=\"2285\" data-end=\"2296\" data-col-size=\"sm\"\u003e512 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2297\" data-end=\"2333\"\u003e\n\u003ctd data-start=\"2297\" data-end=\"2307\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"2307\" data-end=\"2333\" data-col-size=\"sm\"\u003e7-inch LCD Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2334\" data-end=\"2373\"\u003e\n\u003ctd data-start=\"2334\" data-end=\"2349\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"2349\" data-end=\"2373\" data-col-size=\"sm\"\u003e100–240V AC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2374\" data-end=\"2413\"\u003e\n\u003ctd data-start=\"2374\" data-end=\"2391\" data-col-size=\"sm\"\u003eVessel Sealing\u003c\/td\u003e\n\u003ctd data-start=\"2391\" data-end=\"2413\" data-col-size=\"sm\"\u003eUp to 7 mm vessels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2414\" data-end=\"2477\"\u003e\n\u003ctd data-start=\"2414\" data-end=\"2434\" data-col-size=\"sm\"\u003eSafety Monitoring\u003c\/td\u003e\n\u003ctd data-start=\"2434\" data-end=\"2477\" data-col-size=\"sm\"\u003eREM Patient Return Electrode Monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2478\" data-end=\"2521\"\u003e\n\u003ctd data-start=\"2478\" data-end=\"2498\" data-col-size=\"sm\"\u003eControl Interface\u003c\/td\u003e\n\u003ctd data-start=\"2498\" data-end=\"2521\" data-col-size=\"sm\"\u003eDigital Touchscreen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2522\" data-end=\"2555\"\u003e\n\u003ctd data-start=\"2522\" data-end=\"2532\" data-col-size=\"sm\"\u003eCooling\u003c\/td\u003e\n\u003ctd data-start=\"2532\" data-end=\"2555\" data-col-size=\"sm\"\u003eInternal Forced Air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2556\" data-end=\"2609\"\u003e\n\u003ctd data-start=\"2556\" data-end=\"2571\" data-col-size=\"sm\"\u003eInstallation\u003c\/td\u003e\n\u003ctd data-start=\"2571\" data-end=\"2609\" data-col-size=\"sm\"\u003eOperating Theatre \/ Surgical Suite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2610\" data-end=\"2650\"\u003e\n\u003ctd data-start=\"2610\" data-end=\"2626\" data-col-size=\"sm\"\u003eCertification\u003c\/td\u003e\n\u003ctd data-start=\"2626\" data-end=\"2650\" data-col-size=\"sm\"\u003eCE (model dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"2652\" data-end=\"2689\"\u003e \u003c\/p\u003e\n\u003chr data-start=\"2691\" data-end=\"2694\"\u003e\n\u003ch1 data-section-id=\"rrjqh0\" data-start=\"2696\" data-end=\"2724\"\u003eIntelligent Energy Control\u003c\/h1\u003e\n\u003cp data-start=\"2726\" data-end=\"2854\"\u003eThe generator continuously analyses tissue impedance and automatically adjusts energy delivery in real time. This helps provide:\u003c\/p\u003e\n\u003cul data-start=\"2856\" data-end=\"2991\"\u003e\n\u003cli data-section-id=\"sc4u1o\" data-start=\"2856\" data-end=\"2888\"\u003eMore consistent vessel sealing\u003c\/li\u003e\n\u003cli data-section-id=\"1bixe38\" data-start=\"2889\" data-end=\"2913\"\u003eReduced thermal injury\u003c\/li\u003e\n\u003cli data-section-id=\"17vdz10\" data-start=\"2914\" data-end=\"2943\"\u003eImproved surgical precision\u003c\/li\u003e\n\u003cli data-section-id=\"11c2ci9\" data-start=\"2944\" data-end=\"2968\"\u003eFaster tissue response\u003c\/li\u003e\n\u003cli data-section-id=\"15dif4h\" data-start=\"2969\" data-end=\"2991\"\u003eReliable haemostasis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2993\" data-end=\"3169\"\u003eThe system samples electrical parameters hundreds of thousands of times per second to optimise energy delivery throughout each activation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003chr data-start=\"3171\" data-end=\"3174\"\u003e\n\u003ch1 data-section-id=\"14mjx9\" data-start=\"3176\" data-end=\"3193\"\u003eSafety Features\u003c\/h1\u003e\n\u003cul data-start=\"3195\" data-end=\"3425\"\u003e\n\u003cli data-section-id=\"wgqwnm\" data-start=\"3195\" data-end=\"3230\"\u003eReturn Electrode Monitoring (REM)\u003c\/li\u003e\n\u003cli data-section-id=\"1dyrrn4\" data-start=\"3231\" data-end=\"3258\"\u003eAutomatic fault detection\u003c\/li\u003e\n\u003cli data-section-id=\"1wqnqec\" data-start=\"3259\" data-end=\"3288\"\u003eOver-temperature protection\u003c\/li\u003e\n\u003cli data-section-id=\"s0ygxn\" data-start=\"3289\" data-end=\"3308\"\u003eOutput monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"1kqowqt\" data-start=\"3309\" data-end=\"3336\"\u003eAudible and visual alarms\u003c\/li\u003e\n\u003cli data-section-id=\"18y3xt9\" data-start=\"3337\" data-end=\"3370\"\u003eSelf-diagnostic startup testing\u003c\/li\u003e\n\u003cli data-section-id=\"8idazr\" data-start=\"3371\" data-end=\"3397\"\u003eShort-circuit protection\u003c\/li\u003e\n\u003cli data-section-id=\"hx1h0r\" data-start=\"3398\" data-end=\"3425\"\u003ePatient safety monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3427\" data-end=\"3430\"\u003e\n\u003ch1 data-section-id=\"kxdk86\" data-start=\"3432\" data-end=\"3456\"\u003eCompatible Accessories\u003c\/h1\u003e\n\u003cp data-start=\"3458\" data-end=\"3490\"\u003eCompatible with a wide range of:\u003c\/p\u003e\n\u003cul data-start=\"3492\" data-end=\"3647\"\u003e\n\u003cli data-section-id=\"w1q0pv\" data-start=\"3492\" data-end=\"3519\"\u003eVessel sealing handpieces\u003c\/li\u003e\n\u003cli data-section-id=\"3kgjs5\" data-start=\"3520\" data-end=\"3539\"\u003eMonopolar pencils\u003c\/li\u003e\n\u003cli data-section-id=\"puofh9\" data-start=\"3540\" data-end=\"3557\"\u003eBipolar forceps\u003c\/li\u003e\n\u003cli data-section-id=\"1h0k6n9\" data-start=\"3558\" data-end=\"3585\"\u003ePatient return electrodes\u003c\/li\u003e\n\u003cli data-section-id=\"153ut4u\" data-start=\"3586\" data-end=\"3600\"\u003eFootswitches\u003c\/li\u003e\n\u003cli data-section-id=\"vj80ia\" data-start=\"3601\" data-end=\"3647\"\u003eReusable and disposable surgical instruments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3649\" data-end=\"3705\"\u003e(Compatibility depends on the specific generator model.)\u003c\/p\u003e\n\u003chr data-start=\"3707\" data-end=\"3710\"\u003e\n\u003ch1 data-section-id=\"b8y6te\" data-start=\"3712\" data-end=\"3722\"\u003eBenefits\u003c\/h1\u003e\n\u003cul data-start=\"3724\" data-end=\"4000\"\u003e\n\u003cli data-section-id=\"n3gv01\" data-start=\"3724\" data-end=\"3749\"\u003eReliable vessel sealing\u003c\/li\u003e\n\u003cli data-section-id=\"18bgld\" data-start=\"3750\" data-end=\"3783\"\u003eReduced intraoperative bleeding\u003c\/li\u003e\n\u003cli data-section-id=\"934cmm\" data-start=\"3784\" data-end=\"3814\"\u003eExcellent surgical precision\u003c\/li\u003e\n\u003cli data-section-id=\"5lg7ei\" data-start=\"3815\" data-end=\"3843\"\u003eEasy touchscreen operation\u003c\/li\u003e\n\u003cli data-section-id=\"14mrxuk\" data-start=\"3844\" data-end=\"3869\"\u003eMultiple surgical modes\u003c\/li\u003e\n\u003cli data-section-id=\"g0s4fj\" data-start=\"3870\" data-end=\"3882\"\u003eFast setup\u003c\/li\u003e\n\u003cli data-section-id=\"1l1czv0\" data-start=\"3883\" data-end=\"3902\"\u003eCompact footprint\u003c\/li\u003e\n\u003cli data-section-id=\"1dmfrcs\" data-start=\"3903\" data-end=\"3948\"\u003eSuitable for high-volume operating theatres\u003c\/li\u003e\n\u003cli data-section-id=\"1bhmmy0\" data-start=\"3949\" data-end=\"4000\"\u003eSupports both open and minimally invasive surgery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4002\" data-end=\"4005\"\u003e\n\u003ch1 data-section-id=\"hg9dub\" data-start=\"4007\" data-end=\"4025\"\u003ePackage Includes\u003c\/h1\u003e\n\u003cul data-start=\"4027\" data-end=\"4162\"\u003e\n\u003cli data-section-id=\"15buy15\" data-start=\"4027\" data-end=\"4054\"\u003eElectrosurgical Generator\u003c\/li\u003e\n\u003cli data-section-id=\"m9yum6\" data-start=\"4055\" data-end=\"4068\"\u003ePower Cable\u003c\/li\u003e\n\u003cli data-section-id=\"10sdtyb\" data-start=\"4069\" data-end=\"4082\"\u003eUser Manual\u003c\/li\u003e\n\u003cli data-section-id=\"svgewu\" data-start=\"4083\" data-end=\"4122\"\u003eAccessories (configuration dependent)\u003c\/li\u003e\n\u003cli data-section-id=\"1ar3ill\" data-start=\"4123\" data-end=\"4162\"\u003eOptional Footswitch (model dependent)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4164\" data-end=\"4167\"\u003e\n\u003ch1 data-section-id=\"3yvmz6\" data-start=\"4169\" data-end=\"4179\"\u003eWarranty\u003c\/h1\u003e\n\u003cul data-start=\"4181\" data-end=\"4359\"\u003e\n\u003cli data-section-id=\"17qh3fz\" data-start=\"4181\" data-end=\"4261\"\u003eManufacturer's warranty available (typically 12 months, depending on supplier)\u003c\/li\u003e\n\u003cli data-section-id=\"12m7h16\" data-start=\"4262\" data-end=\"4359\"\u003eTechnical support available from authorised distributors.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"SutureVet","offers":[{"title":"Default Title","offer_id":58475833426265,"sku":"BT-VET-UL","price":299.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1039\/1984\/5721\/files\/ElectricScalpelVesselSealingLigasureforVeterinaryUse.png?v=1783032637","url":"https:\/\/www.suturevet.co.uk\/products\/electric-scalpel-vessel-sealing-ligasure-for-veterinary","provider":"SutureVet","version":"1.0","type":"link"}