Collection details
SutureVet's braided dental veterinary sutures offer excellent knot security and superior handling characteristics in the challenging wet environment of the oral cavity. The multifilament braided construction ties smoothly and holds knots reliably — a critical advantage when working in the confined, moisture-rich spaces of intraoral surgery where knot integrity directly impacts wound closure success.
Our braided dental suture range includes absorbable polyglactin options that dissolve predictably within the mucosal healing timeframe, eliminating the need for suture removal in a location that is difficult to access and stressful for the patient. Fine gauges and atraumatic needle profiles are selected specifically for veterinary dental applications including tooth extractions, gingival flap closure, and oral soft tissue repair in dogs, cats, and other veterinary species.
While braided sutures have greater surface area than monofilament options, modern coated braided dental sutures minimise tissue drag and bacterial wicking, making them a clinically sound choice for many intraoral applications. All products are supplied sterile and individually packaged from ISO-certified manufacturers.
Order online with fast UK dispatch and competitive trade pricing from SutureVet.
1534 products
Sort by:
1534 products
This PROLENE Polypropylene Blue Non-Absorbable Surgical Suture, product code W8684G, is engineered for reliable skin and soft tissue approximation where precision handling and long-term tensile stability are essential. Manufactured from non-absorbable polypropylene monofilament, PROLENE provides smooth tissue passage, minimal inflammatory response and permanent wound support.
The USP 3-0 diameter delivers balanced tensile performance suitable for dermal and moderate-tension soft tissue closure. The 45 cm strand length supports accurate placement and secure knot tying across a wide range of surgical procedures.
This suture is supplied with an FS reverse cutting needle (26 mm), manufactured from 420 alloy for strength and durability. The reverse cutting configuration enhances needle stability and reduces tissue cut-through risk, making it particularly suitable for skin and tougher dermal layers. Supplied sterile and single-use in a box of 12, this product is intended for professional surgical environments requiring dependable non-absorbable wound closure.
- Key Features
- Non-absorbable polypropylene monofilament
- USP 3-0 surgical diameter
- 45 cm strand length
- FS needle design
- 26 mm reverse cutting needle
- 420 alloy needle construction
- Designed for dermal and tougher tissue penetration
- Minimal tissue reactivity
- Sterile, single-use — Box of 12
- Technical Specifications
- Brand: PROLENE
- Manufacturer: Ethicon
- Product Code: W8684G
- Category: Ethicon Wound Closure
- Suture Size: USP 3-0
- Length: 45 cm
- Colour: Blue
- Material: Polypropylene
- Absorbability: Non-absorbable
- Directionality: Unidirectional
- Needle Name: FS
- Needle Length: 26 mm
- Needle Point Type: Reverse Cutting
- Needle Alloy: 420
- Pledget: No
- Strands per Pack: 1
- Quantity per Box: 12
- Unit of Measure: Box (12 Each)
- Suitable For
- Dermal wound closure
- Skin approximation
- Moderate-tension soft tissue repair
- General surgical procedures
- Applications requiring durable non-absorbable suturing
This PROLENE Polypropylene Blue Non-Absorbable Surgical Suture, product code W8761G, is engineered for reliable soft tissue and dermal approximation where precision handling and permanent tensile strength are required. Manufactured from non-absorbable polypropylene monofilament, PROLENE provides smooth tissue passage, minimal inflammatory response and long-term wound stability.
The USP 4-0 diameter delivers balanced tensile performance suitable for fine soft tissue and layered closure procedures. The extended 90 cm strand length supports efficient continuous suturing and controlled knot placement in deeper or more complex surgical applications.
This suture is bi-directional and supplied double-armed with two SH-2 taper point needles (20 mm). The taper point configuration enables atraumatic penetration by separating tissue fibres rather than cutting, helping to minimise tissue trauma during approximation. Supplied sterile and single-use in a box of 12, this product is intended for professional surgical environments requiring dependable non-absorbable wound closure.
- Key Features
- Non-absorbable polypropylene monofilament
- USP 4-0 surgical diameter
- 90 cm strand length
- Bi-directional, double-armed configuration
- SH-2 needle design (2 × 20 mm)
- Taper point needle configuration
- Smooth, atraumatic tissue penetration
- Minimal tissue reactivity
- Sterile, single-use — Box of 12
- Technical Specifications
- Brand: PROLENE
- Manufacturer: Ethicon
- Product Code: W8761G
- Category: Ethicon Wound Closure
- Suture Size: USP 4-0
- Length: 90 cm
- Colour: Blue
- Material: Polypropylene
- Absorbability: Non-absorbable
- Directionality: Bi-directional
- Needle Name: SH-2 (×2)
- Needle Length: 20 mm
- Needle Point Type: Taper Point
- Pledget: No
- Strands per Pack: 1
- Quantity per Box: 12
- Unit of Measure: Box (12 Each)
- Suitable For
- Fine soft tissue approximation
- Dermal wound closure
- Layered or continuous suturing techniques
- Plastic and reconstructive procedures
- Applications requiring durable non-absorbable suturing
This PROLENE Polypropylene Blue Non-Absorbable Surgical Suture, product code W8770G, is engineered for dependable soft tissue and dermal approximation where precision handling and long-term tensile strength are required. Manufactured from non-absorbable polypropylene monofilament, PROLENE provides smooth tissue passage, minimal inflammatory response and permanent wound stability.
The USP 3-0 diameter delivers balanced tensile performance suitable for moderate-tension soft tissue and layered closure procedures. The 75 cm strand length supports accurate placement and secure knot tying during routine and specialist surgical applications.
This suture is fitted with an SH-1 taper point needle (22 mm). The taper point configuration enables atraumatic penetration by separating tissue fibres rather than cutting, helping to minimise tissue trauma while maintaining controlled placement. Supplied sterile and single-use in a box of 12, this product is intended for professional surgical environments requiring dependable non-absorbable wound closure.
- Key Features
- Non-absorbable polypropylene monofilament
- USP 3-0 surgical diameter
- 75 cm strand length
- SH-1 needle design
- 22 mm taper point needle
- Smooth, atraumatic tissue penetration
- Minimal tissue reactivity
- Permanent wound support
- Sterile, single-use — Box of 12
- Technical Specifications
- Brand: PROLENE
- Manufacturer: Ethicon
- Product Code: W8770G
- Category: Ethicon Wound Closure
- Suture Size: USP 3-0
- Length: 75 cm
- Colour: Blue
- Material: Polypropylene
- Absorbability: Non-absorbable
- Directionality: Unidirectional
- Needle Name: SH-1
- Needle Length: 22 mm
- Needle Point Type: Taper Point
- Pledget: No
- Strands per Pack: 1
- Quantity per Box: 12
- Unit of Measure: Box (12 Each)
- Suitable For
- Soft tissue approximation
- Dermal wound closure
- Layered surgical closure
- General surgical procedures
- Applications requiring durable non-absorbable suturing
This PROLENE Polypropylene Blue Non-Absorbable Surgical Suture, product code W8850, is engineered for dependable soft tissue and fascial approximation where enhanced tensile strength and extended reach are required. Manufactured from non-absorbable polypropylene monofilament, PROLENE ensures smooth tissue passage, minimal inflammatory response and permanent wound stability.
The USP 2-0 diameter delivers substantial tensile performance suitable for moderate to high-tension soft tissue closure. The extended 90 cm strand length supports efficient layered or continuous suturing techniques during surgical procedures.
This suture is bi-directional and supplied double-armed with two CC-30 TAPERCUT needles (31 mm), manufactured from 4310 alloy for strength and consistency. The TAPERCUT configuration combines a tapered body with a cutting tip, enabling controlled penetration of slightly resistant or fibrous tissue while maintaining stability and accuracy. Supplied sterile and single-use in a box of 12, this product is intended for professional surgical environments requiring dependable non-absorbable wound closure.
- Key Features
- Non-absorbable polypropylene monofilament
- USP 2-0 surgical diameter
- 90 cm strand length
- Bi-directional, double-armed configuration
- CC-30 needle design (2 × 31 mm)
- TAPERCUT needle configuration
- 4310 alloy needle construction
- Controlled penetration of fibrous tissue
- Sterile, single-use — Box of 12
- Technical Specifications
- Brand: PROLENE
- Manufacturer: Ethicon
- Product Code: W8850
- Category: Ethicon Wound Closure
- Suture Size: USP 2-0
- Length: 90 cm
- Colour: Blue
- Material: Polypropylene
- Absorbability: Non-absorbable
- Directionality: Bi-directional
- Needle Name: CC-30 (×2)
- Needle Length: 31 mm
- Needle Point Type: TAPERCUT
- Needle Alloy: 4310
- Pledget: No
- Strands per Pack: 1
- Quantity per Box: 12
- Unit of Measure: Box (12 Each)
- Suitable For
- Fascial closure
- Moderate to high-tension soft tissue repair
- Layered surgical closure
- General surgical procedures
- Applications requiring durable non-absorbable suturing
This PROLENE Polypropylene Blue Non-Absorbable Surgical Suture, product code W8852, is engineered for dependable soft tissue and fascial approximation where enhanced tensile strength and extended reach are required. Manufactured from non-absorbable polypropylene monofilament, PROLENE ensures smooth tissue passage, minimal inflammatory response and permanent wound stability.
The USP 2-0 (Metric 3) diameter delivers substantial tensile performance suitable for moderate to high-tension soft tissue closure. The extended 90 cm strand length supports efficient layered or continuous suturing techniques during surgical procedures.
This suture is fitted with a CC-40 TAPERCUT needle. The TAPERCUT configuration combines a tapered body with a cutting tip, enabling controlled penetration of slightly resistant or fibrous tissue while maintaining stability and precision. Supplied sterile and single-use in a box of 12, this product is intended for professional surgical environments requiring dependable non-absorbable wound closure.
- Key Features
- Non-absorbable polypropylene monofilament
- USP 2-0 (Metric 3) surgical diameter
- 90 cm strand length
- CC-40 needle design
- TAPERCUT needle configuration
- Controlled penetration of fibrous tissue
- Minimal tissue reactivity
- Permanent wound support
- Sterile, single-use — Box of 12
- Technical Specifications
- Brand: PROLENE
- Manufacturer: Ethicon
- Product Code: W8852
- Product Group: Non-Absorbable Sutures
- Category: Wound Closure
- Suture Size: USP 2-0 (Metric 3)
- Length: 90 cm
- Colour: Blue
- Material: Polypropylene
- Absorbability: Non-absorbable
- Needle Name: CC-40
- Needle Point Type: TAPERCUT
- Quantity per Box: 12
- Unit of Measure: Box (12 Each)
- Suitable For
- Fascial closure
- Moderate to high-tension soft tissue repair
- Layered surgical closure
- General surgical procedures
- Applications requiring durable non-absorbable suturing
This PROLENE Polypropylene Blue Non-Absorbable Surgical Suture, product code W8879T, is engineered for reliable dermal and soft tissue approximation where controlled penetration and long-term tensile stability are required. Manufactured from non-absorbable polypropylene monofilament, PROLENE ensures smooth tissue passage, minimal inflammatory response and permanent wound support.
The USP 4-0 diameter provides balanced tensile performance suitable for dermal and moderate-tension soft tissue closure. The 45 cm strand length supports accurate placement and secure knot tying during routine and specialist surgical procedures.
This suture is fitted with a PC-25 PRIME™ conventional cutting needle (26 mm). The conventional cutting configuration enables sharp penetration of skin and tougher tissue layers, while PRIME™ geometry enhances needle strength and stability during passage. Supplied sterile and single-use in a box of 24, this product is intended for professional surgical environments requiring dependable non-absorbable wound closure.
- Key Features
- Non-absorbable polypropylene monofilament
- USP 4-0 surgical diameter
- 45 cm strand length
- PC-25 PRIME™ needle
- 26 mm conventional cutting needle
- Designed for dermal and tougher tissue penetration
- Minimal tissue reactivity
- Permanent wound support
- Sterile, single-use — Box of 24
- Technical Specifications
- Brand: PROLENE
- Manufacturer: Ethicon
- Product Code: W8879T
- Category: Ethicon Wound Closure
- Suture Size: USP 4-0
- Length: 45 cm
- Colour: Blue
- Material: Polypropylene
- Absorbability: Non-absorbable
- Directionality: Unidirectional
- Needle Name: PC-25 PRIME™
- Needle Length: 26 mm
- Needle Point Type: Conventional Cutting (PC)
- Pledget: No
- Strands per Pack: 1
- Quantity per Box: 24
- Unit of Measure: Box (24 Each)
- Suitable For
- Skin closure
- Dermal wound approximation
- Moderate-tension soft tissue repair
- General surgical procedures
- Applications requiring durable non-absorbable suturing
This PROLENE™ Polypropylene Blue Non-Absorbable Surgical Suture, product code W8880T, is engineered for reliable dermal and soft tissue approximation where controlled penetration and long-term tensile strength are required. Manufactured from non-absorbable polypropylene monofilament, PROLENE™ provides smooth tissue passage, minimal inflammatory response and permanent wound stability.
The USP 3-0 (Metric 2) diameter delivers enhanced tensile performance suitable for dermal and moderate-tension soft tissue closure. The 45 cm strand length supports accurate placement and secure knot tying during routine and specialist surgical procedures.
This suture is fitted with a PC-25 conventional cutting needle. The conventional cutting configuration enables sharp penetration of skin and tougher tissue layers, supporting controlled and precise dermal closure. Supplied sterile and single-use in a box of 24, this product is intended for professional surgical environments requiring dependable non-absorbable wound closure.
- Key Features
- Non-absorbable polypropylene monofilament
- USP 3-0 (Metric 2) surgical diameter
- 45 cm strand length
- PC-25 needle design
- Conventional cutting needle configuration
- Designed for dermal and tougher tissue penetration
- Minimal tissue reactivity
- Permanent wound support
- Sterile, single-use — Box of 24
- Technical Specifications
- Brand: PROLENE™
- Manufacturer: Ethicon
- Product Code: W8880T
- Product Group: Non-Absorbable Sutures
- Category: Wound Closure
- Suture Size: USP 3-0 (Metric 2)
- Length: 45 cm
- Colour: Blue
- Material: Polypropylene
- Absorbability: Non-absorbable
- Needle Name: PC-25
- Needle Point Type: Conventional Cutting
- Quantity per Box: 24
- Unit of Measure: Box (24 Each)
- Suitable For
- Skin closure
- Dermal wound approximation
- Moderate-tension soft tissue repair
- General surgical procedures
- Applications requiring durable non-absorbable suturing
This PROLENE Polypropylene Blue Non-Absorbable Surgical Suture, product code W8895, is designed for dependable soft tissue approximation where long-term tensile strength and minimal tissue reactivity are required. Manufactured from non-absorbable polypropylene monofilament, PROLENE provides smooth tissue passage, excellent knot security and permanent wound support.
The USP 3-0 diameter offers balanced tensile performance and handling characteristics suitable for general soft tissue closure across a range of surgical disciplines. The extended 120 cm strand length supports continuous suturing techniques and controlled placement in procedures requiring longer running closure.
This suture is supplied with a V-7 tapercut needle (26 mm). The tapercut configuration combines a taper body with a cutting tip, enabling controlled penetration of dense or fibrous tissue while reducing unnecessary trauma. Manufactured from high-quality 4310 alloy, the needle provides strength, stability and resistance to bending during placement.
Supplied sterile and single-use in a box of 12, this product is intended for professional surgical environments requiring reliable non-absorbable wound closure.
- Key Features
- Non-absorbable polypropylene monofilament
- USP 3-0 surgical diameter
- 120 cm strand length
- V-7 needle
- 26 mm tapercut needle
- 4310 needle alloy construction
- Minimal tissue reactivity
- Long-term tensile strength
- Sterile, single-use — Box of 12
- Technical Specifications
- Brand: PROLENE
- Manufacturer: Ethicon
- Product Code: W8895
- Category: Ethicon Wound Closure
- Suture Size: USP 3-0
- Length: 120 cm
- Colour: Blue
- Material: Polypropylene
- Absorbability: Non-absorbable
- Directionality: Bi-directional
- Needle Name: V-7
- Needle Length: 26 mm
- Needle Point Type: Tapercut
- Needle Alloy: 4310
- Pledget: No
- Strands per Pack: 1
- Quantity per Box: 12
- Unit of Measure: Box (12 Each)
- Suitable For
- General soft tissue approximation
- Fascial and fibrous tissue closure
- Continuous suturing techniques
- Cardiovascular and general surgical procedures
- Applications requiring permanent non-absorbable support
